ADVANCE

Troubleshooting

Reading a Failed Bond: Adhesive, Cohesive or Substrate Failure

A failed bond is evidence, and the two broken faces record where the weakest link was. Before anyone changes the adhesive, look at where the adhesive stayed: that one observation separates a surface problem from a cure problem from a design problem.

Illustration for Reading a Failed Bond

Symptoms

The report that reaches the engineer is usually just "the part came off". Before it is cleaned, re-bonded or thrown away, look at the two faces under good light and classify them. Three patterns cover almost every case, and a fourth, mixed, is the most common in practice.

  • One face is clean, the other carries all the adhesive: adhesive (interfacial) failure
  • Both faces carry adhesive and the fracture runs through it: cohesive failure
  • The part itself broke, tore or delaminated and the bond line is intact: substrate failure
  • Patches of each on the same face: mixed failure

Adhesive failure: the surface was the weak link

When the adhesive separates cleanly from one surface and the cured film stays whole on the other, the adhesive was stronger than its grip on that surface. The cause sits at the interface: contamination such as oil, mold release, fingerprints or dust; a surface the adhesive cannot wet, such as a low-surface-energy plastic or a passive plating; or the wrong adhesive family for that material. Incomplete cure at the interface, for example a cyanoacrylate on a very dry or acidic surface, shows the same pattern.

Note which side was clean. If it is always the same material, the problem is that material or its finish: check the cleaning step, the supplier and whether the TDS calls for a primer or activator. If the clean side alternates, suspect contamination that varies from part to part, such as handling after cleaning.

Cohesive failure: the adhesive itself gave way

Adhesive on both faces means wetting and adhesion were fine and the load exceeded what the cured adhesive could carry. That is the expected mode when a sound joint is deliberately broken, so cohesive failure above specification is a good result. Cohesive failure below specification points to the adhesive body: incomplete cure (loaded before fixture time, activator missed, a thick bond line uncured in the middle), a gap outside the product’s range, a brittle grade under impact or peel, or an overloaded design.

Look at the texture. A glassy, smooth fracture suggests a brittle adhesive broken by shock or peel; a soft, gummy or tacky layer suggests under-cure; voids and bubbles suggest air trapped during dispensing or a gap too large for the grade.

Substrate failure and mixed modes

If the material broke, tore or delaminated while the bond line held, the bond is stronger than the part. The adhesive is not the problem. Either the joint is loaded beyond the material, the stress is concentrated at an edge, or a weak layer such as paint, oxide, plating or the skin of a molded part separated from its own base. Look at the design and the surface layers, not the adhesive.

Mixed failure, patches of adhesive next to clean areas, is the normal picture on real parts and is read by proportion. Mostly cohesive with a few clean spots says the process is sound but one region was contaminated or starved. Mostly clean with a few cohesive islands says the surface is the issue. Estimate the cohesive area as a percentage and record it; the trend over several parts is more useful than any single one.

What the faces show, and what to check next

The table is the quick reference for the inspection bench. Photograph the faces before using it, because handling smears the evidence.

What you seeModeMost likely causesNext check
One face clean, film intact on the otherAdhesiveContamination, unwettable surface, wrong family, no primerCleaning step, material finish, primer or activator note in the TDS
Adhesive on both faces, broke above specCohesiveNormal: the joint did its jobNone; record the value as the baseline
Adhesive on both faces, soft or tackyCohesiveUnder-cure: loaded early, thick bond line, activator missedTime to load against the TDS fixture time; gap
Adhesive on both faces, glassy, after a knockCohesiveBrittle grade under impact or peelLoad type; consider a toughened grade
Voids or bubbles in the adhesive layerCohesiveAir entrapment, starved joint, gap too largeDispensing method, quantity, gap measurement
Part broke, bond line intactSubstrateOverload, stress concentration, weak surface layerJoint design, edge geometry, paint or plating adhesion
Patches of each on one faceMixedLocal contamination or starvation on a sound processEstimate percentage cohesive; map where the clean spots sit

Documenting a failed part

A failed part without its history is a guess. The diagnostic sequence below is also the record to keep with the part; a sealed bag, a label and five minutes at the time of failure save days later.

  • 1. Photograph both faces before touching them, with a scale reference and under raking light so texture shows
  • 2. Classify the mode: adhesive, cohesive, substrate or mixed, with an estimated percentage of cohesive area
  • 3. Record the product, batch number, bottle opening date, and the activator or primer used, if any
  • 4. Record where the part was in the line, who assembled it, and the time from dispensing to assembly and from assembly to first load
  • 5. Record temperature and humidity at the station, and any heat, wash, solvent or vibration the part saw after bonding
  • 6. Pull an unused part from the same batch and wipe its bond face with a clean white cloth; residue on the cloth is a contamination finding
  • 7. Bag the part with its record and keep it until the root cause is closed

Joint design basics the faces reveal

Adhesives are strongest in shear and compression, where the whole bond area shares the load, and weakest in peel and cleavage, where the load concentrates on a line at the edge and unzips the joint. A fracture that starts at one edge and runs across is a peel or cleavage signature; no change of adhesive fixes that, the design has to turn the peel into shear with an overlap, a flange or a stop.

Bond area and gap come next. Strength scales with area, so a small cohesive face that failed below spec may simply be too small. Gap should sit in the range the TDS gives: too thin starves the joint, too thick leaves the middle uncured. A cyanoacrylate wants a thin, close-fitting line; a structural acrylic paste tolerates more, within its stated maximum.

Change the product or change the process

The mode decides. Adhesive failure is almost always a process fix: cleaning, handling, primer or activator. Cohesive failure below spec is a cure or selection question. Substrate failure is a design question. Change the product only when the faces say the chemistry is wrong for the load or the material.

  • Glassy cohesive fracture under impact or peel: a rubber-toughened cyanoacrylate such as LOCTITE 480 or LOCTITE 435, both described for peel and impact loads
  • Metal-to-metal or magnet joint that needs more than a thin instant adhesive film: a toughened structural acrylic such as LOCTITE AA 331, described for metal bonding, magnet bonding and DC motor assembly
  • Threaded joint where the product stayed liquid on one side: check the process first; LOCTITE 243 is described as oil tolerant and primerless on passive metals
  • Rework: LOCTITE SF 768 is described for removing cured cyanoacrylate and debonding parts; clean back to bare substrate before re-bonding
  • Substrate failure or an edge-started fracture: redesign the joint for shear; a stronger adhesive only breaks the part sooner

Products mentioned in this guide

  • LOCTITE 480

    LOCTITE

    LOCTITE 480

    Product code: 480

    LOCTITE 480 is a black, rubber-toughened instant adhesive for close-fitting parts that face shock or peel loads, with added flexibility on metals, plastics and rubbers.

  • LOCTITE 435

    LOCTITE

    LOCTITE 435

    Product code: 435

    LOCTITE 435 is a rubber-toughened instant adhesive for parts under impact and shock, bonding metals, plastics, rubber, magnets and porous or acidic surfaces.

  • LOCTITE AA 331

    LOCTITE

    LOCTITE AA 331

    Product code: AA 331

    LOCTITE AA 331 is a toughened, medium-viscosity acrylic paste used with LOCTITE SF 7387 activator for metal bonding in DC motors, magnets and pre-coated sheet metal.

  • LOCTITE 243

    LOCTITE

    LOCTITE 243

    Product code: 243

    Blue medium-strength threadlocker for pumps, gearboxes and motors that works on passive metals and tolerates minor oil contamination.

  • LOCTITE SF 768

    LOCTITE

    LOCTITE SF 768

    Product code: SF 768

    Solvent blend for removing cured cyanoacrylate adhesive from surfaces and for debonding parts assembled with it, by wiping or soaking.

Frequently asked questions

Is cohesive failure good or bad?
It depends on the load. Cohesive failure above the specified load is the ideal result: the surfaces held and the adhesive was the limit. Cohesive failure below specification means under-cure, wrong gap, a brittle grade for the load, or an undersized joint.
The adhesive stayed on the metal and came off the plastic. Which side is wrong?
The plastic side. Adhesive failure on one material points at that material: mold release, a low-energy plastic that needs a primer, or a surface the adhesive family cannot wet. Check the cleaning step and the primer note in the TDS before changing anything else.
The part broke before the bond did. Should I use a weaker adhesive?
No. Substrate failure means the joint is loaded beyond the material or the stress is concentrated at an edge. Spread the load over more area, move it into shear, or strengthen the part; the adhesive is already doing its job.
How many failed parts do I need before changing anything?
One documented part is enough to start checking the process; a product change should wait for a pattern across several parts with the same mode. Changing the adhesive after one mixed-mode failure usually hides the real cause.

Related solutions

Send us the photos

Two photos of the broken faces, the product and batch, and the two materials are enough for a first reading. We will tell you whether to look at the surface, the cure or the design, and which TDS to open.

Not sure which product fits? Ask our assistant

Type the job, the material or a spec. It searches our published products and TDS values — no external AI.